Vacon Drives
  1. Power: 1/4 - 600 HP variable frequency drives
  2. Models: NXP, Vacon 100, Vacon 20 CP, X-Series
  3. Reliable, robust, time proven
  4. Ideal for demanding applications
  5. Controls induction and permanent magnet motors
  6. Multiple protocols supported via options cards
Image is not available

Vacon Drives

Image is not available
Vacon Drives
  1. Power: 1/4 - 600 HP variable frequency drives
  2. Models: NXP, Vacon 100, Vacon 20 CP, X-Series
  3. Reliable, robust, time proven
  4. Ideal for demanding applications
  5. Controls induction and permanent magnet motors
  6. Multiple protocols supported via options cards
Image is not available

Vacon Drives

Image is not available
previous arrow
next arrow

Vacon NXP Wall-mounted

Vacon NXP (NX professional series) wall-mounted VFD is a compact and comprehensive drive package. Engineered with all the necessary components, integrated into a single frame. The NXP drives are designed to handle high inertia, overhauling loads of both induction and permanent magnet (PM) motors, gear-less drive applications and paralleling solutions.

Wall-mounted NXP drives are available in compact NEMA Type 1 (IP21) and NEMA Type 12 (IP54) enclosures.

The NXP wall-mounted units are equipped with internal EMC filtering with power electronics integrated into an all-metal frame. Smaller frame sizes (FR4-FR6) have an integrated brake-chopper as standard and the 380-500 Vac units can be equipped with an integrated brake resistor. Larger frames (FR7-FR12) can be equipped with an integrated brake-chopper as an option.

NXP drives are the smart drive of choice. With exceptional programming flexibility and fast fieldbus I/O the NXP drives can easily be integrated into any automation system.

sai drive solutions vacon nxp wallmount drives 382x

Features

- Controls induction and permanent magnet motors
- Reliable, robust performance, engineered for demanding applications
- UL listed disconnected switch and ultra rapid AC fuses
- Frame 4 to Frame 6 includes integrated brake-chopper, Frame 7 to Frame 12 have integrated break-chopper as an option
- Wide array of I/O communication cards (OPT cards)
- Fast drive-to-drive communication
- DC-link bus terminal connections
- Dynamic open and closed loop vector control
- 50° C ambient rating, no derate
- Wall-mounted NXPs & option cards in SAI stock


Specifications

Main Connections

Input Voltage

208…240 V;
380…500 V;
500…690 V;
–10%…+10%

Input frequency

45…66 Hz

Connection to mains

Once per minute or less

Starting delay

2 s (FR4 to FR8); 5 s (FR9)

Network imbalance

Max. ±3% of nominal voltage

Supply Network

Networks

 TN, TT, IT

Short circuit current

 Maximum short circuit current has to be < 100 kA.

Motor Connections

Output voltage

0–Uin

Continuous output current

IH: Ambient temperature max. +50°C, overload 1.5 x IH (1 min./10 min.)
IL: Ambient temperature max. +40°C, overload 1.1 x IL (1 min./10 min.)

Starting current

IS for 2 s every 20 s; After 2 s current controller forces it down to 150% IH.

Output frequency

0…320 Hz (standard NXP and NXS);
7200 Hz (special NXP with special software)

Frequency resolution

0.01 Hz (NXS); Application dependent (NXP)

Control Characteristics

Control method

Frequency control U/f
Open Loop Sensorless Vector Control
Closed Loop Vector Control (NXP only)

Switching frequency (see parameter 2.6.9)

NX_2/NX_5: Up to NX_0061: 1…16 kHz; Default: 10 kHz
NX_2: NX_0075 and greater: 1...10 kHz; Def: 3.6 kHz
NX_5: NX_0072 and greater: 1…6 kHz; Def: 3.6 kHz
NX_6: 1…6 kHz; Default: 1.5 kHz

Frequency Reference Analogue input Panel reference

Resolution 0.1% (10-bit), accuracy ±1% Resolution 0.01 Hz

Field weakening point

8…320 Hz

Acceleration time

0.1…3000 sec

Deceleration time

0.1…3000 sec

Braking torque

DC brake: 30% * TN (without brake option)

Ambient Conditions

Ambient operating temperature

FR4-FR9:
IH : –10°C (no frost)…+50°C
IL : –10°C (no frost)…+40°C
FR10-FR12 (IP21):
IH/IL : –10°C (no frost)…+40°C (except NX_0461 6, NX_0590 6,
NXP0820 6 : –10°C (no frost)…+35°C)
FR10 (IP54):
IH/IL : –10°C (no frost)…+40°C (except NX_0520 5, NX_0416 6: –10°C (no frost)…+35°C)

Storage temperature

–40°C…+70°C

Relative humidity

0 to 95% RH, non-condensing, non-corrosive, no dripping water

Air quality

- chemical vapours
- mechanical particles

IEC 60721-3-3, unit in operation, class 3C2
IEC 721-3-3, unit in operation, class 3S2

Altitude

100% load capacity (no derating) up to 1,000 m
1-% derating for each 100 m above 1,000 m.
Max. altitudes: NX_2: 3,000 m; NX_5 (380...400 V):
3,000 m; NX_5 (415...500): 2,000 m; NX_6: 2,000 m

Vibration

EN50178/EN60068-2-6

5…150 Hz
Displacement amplitude 1 mm (peak) at 5…15.8 Hz (FR4…9)
Max acceleration amplitude 1 G at 15.8…150 Hz (FR4…FR9)
Displacement amplitude 0.25 mm (peak) at 5-31 Hz (FR10…12)
Max acceleration amplitude 0.25 G at 31…150 Hz(FR10…12)

Shock

EN50178, EN60068-2-27

UPS Drop Test (for applicable UPS weights)
Storage and shipping: max 15 G, 11 ms (in package)

Enclosure class IP21/NEMA1 standard in entire kW/HP range
IP54/NEMA12 option in FR4 to FR10
Note! Keypad required for IP54/NEMA12
Pollution degree

PD2

EMC (at default settings)

Immunity

Fulfils EN61800-3 (2004), first and second environment.

Emissions

Depend on EMC level. See chapters 2 and 3.

Safety

 

 

EN 61800-5-1 (2007), CE, cUL, C-TICK; (see unit nameplate for more detailed approvals) IEC 60664-1 and UL840 in overvoltage category III.

Emissions

Average noise level (cooling fan) in dB (A) 

FR4 44, FR9 76, FR5 49, FR10 76, FR6 57, FR11 76, FR7 57, FR12 76,
FR8 58


Control Connections (OPTA1, OPTA2 and OPTA3)

Analogue input voltage

0…+10 V, Ri = 200 kΩ, (–10 V…+10 V joystick control) Resolution 0.1%, accuracy ±1%

Analogue input current

0(4)…20 mA, Ri = 250 Ω differential

Digital inputs (6)

Positive or negative logic; 18…30 VDC

Auxiliary voltage

+24 V, ±10%, max volt. ripple < 100 mVrms; max. 250 mA Dimensioning: max. 1000 mA/control box (power backup)

Output reference voltage

+10 V, +3%, max. load 10 mA

Analogue output

0(4)…20 mA; RL max. 500 Ω; Resolution 10 bit; Accuracy ±2%

Digital outputs

Open collector output, 50 mA/48 V

Relay outputs

2 programmable change-over relay outputs
Switching capacity (resistive):
24 VDC/8 A, 250 VAC/8 A, 125 VDC/0.4 A
Min.switching load: 5 V/10 mA

Protections

Overvoltage trip limit 

NX_2: 437 VDC; NX_5: 911 VDC; NX_6: 1200 VDC

Undervoltage trip limit

NX_2: 183 VDC; NX_5: 333 VDC; NX_6: 460 VDC

Earth fault protection

In case of earth fault in motor or motor cable, only the frequency converter is protected

Mains supervision

Trips if any of the input phases is missing

Motor phase supervision

Trips if any of the output phases is missing

Overcurrent protection

Yes

Unit overtemperature protection

Yes

Motor overload protection

Yes* Motor overload protection provided at 110% of full motor load current.

Motor stall protection

Yes

Motor underload protection

Yes

Short-circuit protection of +24 V and +10 V reference voltages

Yes

Models

VACON NXP is an air-cooled AC drive solution for all applications where robustness, dynamic performance, precision and power are required. This series of air-cooled drives can operate with anything from 0.37 kW to 160 kW.

380 - 500 Vac, 50/60 Hz, 3-Ph

 Product Code

      Motor Shaft Power and Current

 Frame

Size

     Heavy Duty (150%)

   Normal Duty (120%)

   HP  kW  Amps  HP  kW

 Amps

NXP0003-5A2H1-SSSA1A2 1 0.75 2.2 1.5 1.1 3.3

F4

NXP0004-5A2H1-SSSA1A2 1.5 1.1 3.3 2 1.5 4.3

F4

NXP0005-5A2H1-SSSA1A2 2 1.5 4.3 3 2.2 5.6

F4

NXP0007-5A2H1-SSSA1A2 3 2.2 5.6 5 3 7.6

F4

NXP0009-5A2H1-SSSA1A2 5 3 7.6 5 4 9

F4

NXP0012-5A2H1-SSSA1A2 5 4 9 7.5 5.5 12

F4

NXP0016-5A2H1-SSSA1A2 7.5 5.5 12 10 7.5 16

F5

NXP0022-5A2H1-SSSA1A2 10 7.5 16 15 11 23

F5

NXP0031-5A2H1-SSSA1A2 15 11 23 20 15 31

F5

NXP0038-5A2H1-SSSA1A2 20 15 31 25 18.5 38

F6

NXP0045-5A2H1-SSSA1A2 25 18.5 38 30 22 46

F6

NXP0061-5A2H1-SSSA1A2 30 22 46 40 30 61

F6

NXP0072-5A2H0-SSSA1A2 40 30 61 50 37 72

F7

NXP0087-5A2H0-SSSA1A2 50 37 72 60 45 87

F7

NXP0105-5A2H0-SSSA1A2 60 45 87 75 55 105

F7

NXP0140-5A2H0-SSSA1A2 75 55 105 100 75 140

F8

NXP0168-5A2H0-SSSA1A2 100 75 140 125 90 170

F8

NXP0205-5A2H0-SSSA1A2 125 90 170 150 110 205

F8

NXP0261-5A2H0-SSFA1A2 150 110 205 200 132 261

F9

NXP0300-5A2H0-SSFA1A2 200 132 245 250 160 300

F9


Frame Size and Weights

  Dimensions (Inches)
Weight
Dimensions (mm)

Weight

  W H D (lbs) W H D

(kg)

Frame 4 5 11.5 7.5 11 128 292 190

5

Frame 5 5.67 15.39 8.5 18 144 391 214

8

Frame 6 7.68 20.5 9.33 41 195 519 237

19

Frame 7 9.33 23.27 10.12 77 237 591 257

35

Frame 8 11.46 30 13.54 128 291 758 344

58

Frame 9 19 45.28 14.25 322 480 1150 362

146


Downloads

For product related downloads including brochures & manuals visit the support resources section by clicking on the link below.

 SAI Drive Solutions Support Downloads Brochures Manuals Tile 382x


Contact Support

For technical support email support@saidrives.com or call 281.516.3130.